Solutions

Sized to your deployment — from a single GPU row to a SuperPOD-scale facility.

SMALL1–8 racks≤ 200 kWAir / RDHX · EthernetMEDIUM8–64 racks0.5–3 MWDLC · InfiniBand · buswayLARGE64+ racks10 MW+Facility water · MV substation
Three reference scales. Each square is one liquid- or air-cooled GPU rack; the bar is facility power.
SMALL · 1–8 RACKS · TO 200 KWRear-door HX · airUPSEthernet fabric · rack PDUs · weeks

Small

1–8 racks · to 200 kW

Air-cooled or rear-door HX GPU rows for enterprise pilots and inference. Ethernet fabric, rack PDUs, single UPS module. Deployed in weeks.

MEDIUM · 8–64 RACKS · 0.5–3 MWROW CDU · BUSWAYDTC liquid · N+1 · IB / Spectrum-X

Medium

8–64 racks · 0.5–3 MW

Direct-to-chip liquid cooling with row CDUs, overhead busway, N+1 power. NVL72-class racks, InfiniBand or Spectrum-X fabric, parallel storage.

LARGE · SUPERPOD · 10 MW+PLANTMV SWITCHGEAR · 800 VDCFull EPC · L1–L5 commissioning

Large

SuperPOD · 10 MW+

Facility-scale water plant, MV switchgear and dedicated substation, 800 VDC-ready distribution, exascale storage. Full EPC delivery and L1–L5 commissioning.

Eight Ways We Engage

Each engagement is a defined scope with its own specifications, delivery phases and acceptance criteria.

NVL72 RACK ROW · LIQUID LOOPCDUSupply 25 °CReturn 45 °C72 GPUs / rack · 132 kW

AI Factory Design & Build

NVL72-class private clusters, from powered shell to first token.

See specifications and phases
RETROFIT · AIR TO DIRECT-TO-CHIPAir · 15 kWDLC · 132 kWSame cage · 6–10 week cutover

Liquid-Cooling Retrofit

Make an existing hall or colo cage NVL72-ready.

See specifications and phases
POWER CHAIN · GRID TO CHIPUtility138 kVSubstn34.5 kVSwitch480 VBusway800 VDCRack132 kWLiquid plant · CDU · dry coolerBTM generation · N+1 · PUE ≤ 1.15

Power & Cooling Infrastructure

Substations, behind-the-meter generation, liquid plants.

See specifications and phases
PREFAB INFERENCE MODULE · 250 KWPOWERUPS · PDUCDU4 racks · 40 ft ISO12.2 mFactory-tested · live in 16 weeks

Edge Inference Modules

Prefab inference sites from 250 kW, delivered and commissioned.

See specifications and phases
CUMULATIVE COST · BUILD VS RENTMonth 14–18RentBuildBreakeventhen 40–60 % saved / yrYears

Build-vs-Rent Advisory

Independent TCO against live neocloud rate cards.

See specifications and phases
CLUSTER SOFTWARE STACKWORKLOADSPyTorch · vLLM · NeMoSCHEDULINGKubernetes · SlurmFABRICQuantum-X IB · Spectrum-XHARDWAREGB300 NVL72 · BlueField

Cluster Bring-up & Software

Kubernetes, Slurm, Mission Control — the neocloud experience, in-house.

See specifications and phases
AIR-GAPPED ENCLAVEYOUR PREMISESGPUGPUGPUPrivate fabric · local KMSNo egress · IL5 · HIPAA · DORA

Sovereign & Air-Gapped AI

Regulated workloads that cannot leave the premises.

See specifications and phases
MANAGED OPERATIONS99.9 %UPTIME SLA24 / 7 / 365NOC coverage≤ 15 minIncident response4 hrSmart-hands on siteMonthlyCapacity report

Managed Operations (NOC)

24/7 monitoring, smart hands, and SLA-backed operations.

See specifications and phases
SECURITY · SITE TO GPU FABRICSITE · fence · CCTVBUILDING · mantrap · badge+bioHALL · cage · rack locksFABRIC · PKEY · VXLANSOC 2 · ISO 27001 · NIST 800-53 · TIA-942

AI Datacenter Security

Physical, network and supply-chain security for GPU facilities — assessed, designed, deployed and certified.

See specifications and phases

Ready to scope your build?

Talk to our engineering team. Every inquiry gets a same-day response and a dedicated solutions engineer.

Start a conversation